WIRES-X guide › Troubleshooting

Port check shows NG

The six UDP ports must be reachable. Work from the PC outward: firewall, fixed address, UPnP, router mapping, then provider.

Symptom: “The WIRES-X software port check reports NG for one or more ports, or the node cannot register.”

Official Yaesu documentationadvancedFTM-100Reviewed

Restates what Yaesu's own manuals say. Sources are listed at the end.

  1. Did you allow the WIRES-X software through the Windows or firewall prompt? If not, the first alert may have been dismissed.
  2. Is the PC's address fixed? A changed address makes the router's forwarding point to the wrong machine.
  3. Does the router have UPnP, and is it enabled? Tick Automatic UPnP in Port check and Start.
  4. If NG remains, add the six UDP ports (46100, 46110, 46112, 46114, 46120, 46122) by hand in the router's NAT or port mapping, pointing at the PC's address.
  5. Check for a second router or modem doing its own address translation. Forward on each one.
  6. If it still fails, ask your provider whether you have a public address of your own.

Sources

Keep reading

← WIRES-X guide