Node network requirements: ports, addresses, firewalls
WIRES-X needs six UDP ports that Yaesu's server can reach, a stable address for the node PC, and a router that forwards correctly.
Restates what Yaesu's own manuals say. Sources are listed at the end.
| Item | Requirement |
|---|---|
| UDP ports | 46100, 46110, 46112, 46114, 46120 and 46122 must be connectable. |
| TCP port | Only when you use the remote monitor function: the default is 46190. |
| Address | A global (public) IP address, dynamic or static. Each node needs its own. |
| Router | Network address and port translation (NAPT) must forward the ports to the node PC. |
| Speed | ADSL 8 Mbps or faster, with a high-speed connection recommended. |
| Other traffic | Heavy use of the same connection can cause audio interruptions or an unstable node. |
Give the node PC a fixed address
When a router passes a port to a PC, it does so by the PC's local address. If the router hands the PC a different address after a restart, the forwarded ports point nowhere and the node stops working. Yaesu's manual shows setting a fixed address on the PC itself within the router's range, taking care that it does not overlap another device.
Opening the ports
- Router with UPnP: enable UPnP on the router, then in the WIRES-X software's Port check window tick Automatic UPnP and click Start. If any port shows NG, the software registers the six ports and checks again.
- Router without UPnP: add the six UDP ports in the router's NAT or port-mapping page, pointing at the node PC's local address.
- If the software still shows NG after UPnP, Yaesu says the software cannot open the ports and you must open them from the router's setup screen.
Remote monitor port
Open TCP 46190 only if you actually use the remote monitor function, and only with the protections described in the safe-operation guide. A node works without it.
Sources
- Official YaesuHRI-200 Instruction Manual (WIRES-X) (opens in a new tab)
Yaesu. Revision 2510-P. Node requirements, registration, software setup, node and room settings.
- Operator guideHow to set up a WIRES-X room (Hamradio.PH) (opens in a new tab)
DU1YQ / N6RJV, Hamradio.PH. An operator guide that says it is not from Yaesu. It quotes WIRES-X software 1.530 as current in March 2020, so treat version-specific details as dated.
Keep reading
Safe node operation and security practice
Keep the node's IDs and PC private, open only the ports required, and treat remote control as optional. What to publish and what not to.
Verified technical explanationFTM-100 · FTM-300 · FTM-400
FTM-100 + HRI-200: setting up a WIRES-X node
The full path from parts to a working node, in the order Yaesu's HRI-200 manual gives it. Do the steps in order; the driver comes before the USB cable.
Official Yaesu documentationFTM-100