WIRES-X guide › Troubleshooting
I hold DX, the X flashes, then it disappears
The radio is searching for a local node and finding none. Work through frequency, mode, band, DG-ID and whether the node is actually up.
Symptom: “The WIRES-X button (DX key) does not connect: the X flashes and then goes away without a node name.”
Restates what Yaesu's own manuals say. Sources are listed at the end.
While the X flashes, the radio is asking for a local node. If nothing answers it gives up: after five minutes on the FTM-100, 30 seconds on the FTM-300 and 20 seconds on the FTM-400 (per each radio's WIRES-X manual). So the question is always the same: why did nothing answer?
Check in this order
- Frequency: is the radio on the node's exact frequency? WIRES-X works only on the operating band: the A band on the FTM-300 and FTM-400.
- Mode: the radio must be in C4FM (AMS or DN), not FM. On the FTM-400, band A must be a mode other than FM. A digital node does not answer FM.
- Is the node digital? If it is an analog node, you cannot find it with DX; connect with DTMF tones in FM.
- DG-ID: the radio's normal DG-ID (TX and RX) should be 00 unless you know the node uses another, and the WIRES-X DG-ID should be AUTO for an open node or the node's number for a restricted one.
- Can you hear the node at all? If you receive its signal, transmit as normal; if you do not, the node may not be on the Internet, or you may be out of range.
- Press DX once while the X is flashing to ask the node again.
Tip. If you hear nothing, test the same frequency with a different radio before blaming yours.
Checked against: FTM-100DR/DE WIRES-X Instruction Manual (opens in a new tab), FTM-300DR/DE WIRES-X Instruction Manual (opens in a new tab), FTM-400XDR/XDE/DR/DE WIRES-X Instruction Manual (opens in a new tab)
Sources
- Official YaesuFTM-100DR/DE WIRES-X Instruction Manual (opens in a new tab)
Yaesu. Revision 1712-D. Connecting, searching, DG-ID, node-station mode on the FTM-100.
- Official YaesuFTM-300DR/DE WIRES-X Instruction Manual (opens in a new tab)
Yaesu. Revision 2007-C. Connecting, searching, DG-ID, node-station mode on the FTM-300.
- Official YaesuFTM-400XDR/XDE/DR/DE WIRES-X Instruction Manual (opens in a new tab)
Yaesu. Revision 1712-G. Connecting, searching, DG-ID, node-station mode on the FTM-400.
Keep reading
DG-ID mismatch: the radio seems deaf
Symptom: “The node is strong but your radio does not hear it or the node does not hear you.”
There are two DG-ID settings on your radio and one on the node. All three have to agree with the node's own rule.
Official Yaesu documentationFTM-100 · FTM-300 · FTM-400
Node found, but no destination connects
Symptom: “The X is lit and the node name shows, but searching the list or connecting to a room fails or shows an error.”
You are talking to the local node, but it cannot reach the destination. The radio shows an error and returns to the list.
Official Yaesu documentationFTM-100 · FTM-300 · FTM-400