WIRES-X guide › Troubleshooting
The node stays in transmit
Open squelch, a stray local signal or answering too fast can hold a node keyed. Disable the offending node and fix the cause.
Symptom: “The node keeps transmitting after an over, or every node in a room is held keyed.”
Restates what Yaesu's own manuals say. Sources are listed at the end.
- If a connected node has open squelch or hears an unknown local signal, all nodes in the room stay in transmission. The owner can temporarily disable that node's connection from the room's Remove/Mute Node setting.
- If a visitor answers too quickly after another node finishes, your node may remain in transmission. Ask visitors to leave a longer gap.
- The HRI-200 cuts off any continuous transmission over three minutes.
Sources
- Official YaesuHRI-200 Instruction Manual (WIRES-X) (opens in a new tab)
Yaesu. Revision 2510-P. Node requirements, registration, software setup, node and room settings.
Keep reading
Running a room: styles, members, reject lists and etiquette
A room is the owner's responsibility. Yaesu gives three styles, member and reject lists, and a short list of operating cautions.
Official Yaesu documentationFTM-100 · FTM-300 · FTM-400