WIRES-X guide › Troubleshooting
The HRI-200 is not detected or behaves oddly
The usual cause is the USB cable having been connected before the driver was installed.
Symptom: “The software cannot see the HRI-200, or audio and control are unreliable after first connection.”
Restates what Yaesu's own manuals say. Sources are listed at the end.
- The manual says to install the HRI-200 driver before connecting the USB cable, and warns that doing otherwise may result in improper operation. Install the driver, then reconnect.
- Clip the ferrite core on the USB cable close to the plug.
- Confirm the radio is in node-station mode and the 10-pin cable is in the radio's DATA jack and the HRI-200 RADIO 1 jack.
- Reinstall the driver from the latest downloads on the product page if it still fails.